aiin perspective

Environment

Electricity, water and carbon.

Research reviewed 13 September 2026

All data centres used 1.5% of global electricity.

2024 estimate · includes AI and non-AI services

All data centres   Other uses

Each square = 1%. This is not AI’s share alone.

The remaining 98.5% includes factories, homes, shops, hospitals, farms and transport. A sector breakdown is shown alongside.

Where does the world’s electricity go?

Final electricity use · 2022 · UN global energy balance

Industry42.3%≈10,389 TWh
Homes27.7%≈6,806 TWh
Commerce & public services18.1%≈4,444 TWh
Other uses10.0%≈2,444 TWh
Transport1.9%≈472 TWh

1 TWh = 1 billion kWh. Other = agriculture and other uses. Shares calculated from rounded UN figures. Data centres are already inside these sectors; do not add 1.5% to this chart.

The two charts answer different questions: all electricity demand in 2024 versus final use by sector in 2022. Final use excludes grid losses and the energy industry’s own electricity use.

Where do AI, streaming, gaming and social media fit? →

A familiar comparison: lighting

Global electricity · 2024 estimates · TWh

Lighting in buildings & outdoors2,200
All data centres415

Lighting excludes industry and agriculture. End uses can overlap sector accounts; these are scale comparisons, not slices to add to the UN chart.

The U.S. breakdown

U.S. electricity retail sales · 2023 · TWh

Homes1,450.0
Commerce & services1,408.1
Industry1,009.3
Transport · mainly rail6.9

Retail sales total 3,874.3 TWh; another 136.9 TWh was used directly by generators. EV charging is distributed across sectors. All U.S. data centres used an estimated 176 TWh in 2023 and overlap these categories.

How fast is data-centre demand growing?

Demand is growing.

All data centres worldwide · TWh per year

Redrawn from IEA figures: ¹2025 report; ²2026 update. Stripes mark the central projection, not a measured outcome.

How much of that could be AI?

2030 central projection · AI-focused facilities

IEA projects roughly half at AI-focused facilities. That is a building classification, not a global measurement of individual AI workloads.

Where are the data centres?

Shares of global electricity used by all data centres · 2024

45%25%15%

U.S.: 45% of the global data-centre total, not 45% of U.S. electricity.

Bubble areas show shares; positions are regional anchors. Other = remainder. Geography: Natural Earth / world-atlas ↗.

Local grid capacity and electricity costs still matter where facilities are concentrated. IEA ↗

AI is one of many data-centre workloads.

All data-centre electricity · worldwide · 2024

15%accelerated servers
85%other servers, cooling and infrastructure

This measures equipment, not AI’s exact share. Some AI runs on ordinary servers; accelerated servers also run non-AI science.

Redrawn from IEA Box 2.1. The 85% remainder includes infrastructure supporting AI, so it is not “85% non-AI.”

A digital service uses more than a data centre.

Your devicePhone, TV or console
NetworksRouter and data transmission
Data centresStorage and computing

Streaming and social feeds can also use AI. These labels overlap; they cannot form a clean AI-versus-everything-else pie chart.

IEA finds no comprehensive global electricity breakdown by application. Data traffic is not an electricity meter.

Gaming and streaming on the same console

One hour · PS5 CFI-2016 · console electricity only

Playing PS5 games · HD average216.8 Wh
Streaming video · HD56.3 Wh

Calculated as measured watts × one hour. Sony tests, January 2024. Excludes TV, router, networks and data centres; not a cloud-gaming estimate.

What a per-use number includes

Examples with different units and boundaries
ActivityReported energyBoundary
Gemini text prompt0.24 Wh / promptGoogle median · May 2025; serving system
Streamed TV112.7 Wh / device-hourUK model · 2021; viewing devices, networks and data centres

A prompt and an hour of viewing are different activities. Neither number establishes total global use, and the Gemini result does not cover every model or task.

What can we say about social media?

Social media uses storage, networking and computing, with AI increasingly mixed into those services. The IEA does not provide an audited global social-media electricity share. Platform-wide sustainability reports also include offices, hardware and other products.

A precise AI-versus-social-media ranking would require consistent workload-level reporting. We leave that share unquantified.

All U.S. data centres · AI and non-AI services · 2023 estimates

Water used at the site, and to supply its power.

Water consumed · billion litres per year

Onsite cooling66
Electricity generation800

The second figure is nearly 800 billion litres, a grid-based estimate. Both cover all U.S. data centres.

Consumed = not returned to the immediate environment, often because it evaporates. USGS ↗

Water use elsewhere

Consumption · billion litres per year

Crop irrigationContiguous U.S. · 2010–20 average
≈104,600
Public water supplyContiguous U.S. · 2010–20 average
≈5,800
Freshwater power-plant coolingContiguous U.S. · 2010–20 average
≈4,000
Textile productionFor EU household purchases · 2022
≈6,000

Context, not a same-year ranking. Textile water includes global supply chains; data-centre cooling counts onsite use. Different years, populations and boundaries prevent a like-for-like efficiency comparison.

A litre consumed in a dry watershed has different consequences from a litre consumed where water is plentiful. Site and season matter. Research ↗

Withdrawal is different from consumption

Water withdrawn is taken from a source. Water consumed is not returned to the immediate environment, for example through evaporation.

Of the water withdrawn, how much is consumed?

Contiguous U.S. · average, 2010–2020

Crop irrigation72%
Public supply12%
Freshwater power-plant cooling4%

Consumed   Returned

Redrawn from USGS consumption and withdrawal estimates, rounded. Water quality and where it returns also matter.

Textiles and cosmetics: what gets counted?

The EEA textile estimate includes fibre production and manufacturing worldwide; about 85% of its water footprint occurs outside Europe. It excludes rainwater.

L’Oréal identifies water use in farming ingredients, manufacturing and rinsing products such as shampoo. That is a wider boundary than cooling a data centre. Its Waterloop factories reuse treated water for industrial processes; this is a company example, not a figure for the entire cosmetics industry.

What about water per AI prompt?
0.24 Whelectricity
0.26 mLonsite cooling water
0.03 g CO₂ecarbon

Google’s reported median Gemini Apps text prompt, May 2025. The water estimate excludes electricity generation. A product-specific median is not a universal prompt footprint or a basis for multiplying out total usage.

Can water use be split into AI, streaming and gaming?

Cooling water is generally reported for a facility or company, not separately for each application. These data-centre totals cannot reliably be divided into AI, social media, streaming and gaming. A facility’s cooling design and local grid also change the result.

Data centres’ share of global carbon emissions

≈0.5%

Of fuel-combustion CO₂, from electricity supplying all data centres in 2024.

About 180 million tonnes CO₂ · AI and non-AI workloads

Excludes hardware, construction and backup generation. This is not AI’s complete carbon footprint.

Heavy industry gives a sense of scale.

14%

Of energy- and process-related emissions comes directly from steel and cement production.

IEA 2025 report. This includes industrial process emissions and excludes purchased electricity; the data-centre figure uses electricity emissions and a fuel-combustion denominator. Context, not a like-for-like lifecycle ranking.

Company emissions, cleaner grids and hardware

Google’s footprint is not zero.

Company-wide emissions · million tonnes CO₂e

202415.9
202518.8

Annual renewable-energy matching does not eliminate the company’s emissions.

Operations, electricity and supply chains across all of Google, not AI alone. GHG Protocol-aligned totals with market-based electricity accounting; chart values rounded.

The electricity source changes the footprint.

61 million tonnes CO₂e: estimated electricity-related emissions from all U.S. data centres in 2023, using regional grids.

1,000 kWh → 400 kg CO₂e

Illustration only. Electricity × intensity ÷ 1,000 = kg CO₂e; excludes hardware and other lifecycle emissions.

Training and hardware also count

One training study

BLOOM’s final training used an estimated 24.7 tonnes CO₂e from dynamic power; adding equipment and other operations raised the estimate to 50.5 tonnes. The larger number includes the smaller and excludes lifetime inference.

Equipment waste

A 2024 model projects 1.2–5.0 million tonnes of cumulative GenAI e-waste for 2020–2030. Longer use and circular strategies lower it by 16–86% across scenarios. These are possible futures, not waste already produced.

Carbon-neutral, net zero and clean electricity
Annual renewable matching
Renewable electricity purchases equal yearly consumption. This does not mean clean power reaches each site every hour.
Carbon-neutral
A claim may balance a defined footprint with offsets. Check the scope, year and reductions achieved.
Net zero
Deep emissions cuts across operations and supply chains, with durable removals for the residual. A target is not an achieved result.

Practical responses · recommendations based on the linked research

Use less energy per task

Test smaller, task-specific models and tune GPU power limits. An MIT-led training example saved about 15% energy with a small runtime increase; savings depend on the workload.

Improve the hardware

Compress models, keep useful equipment in service and measure energy per completed task. MIT’s TinyChat reports memory and speed gains; these are not equivalent carbon savings.

Use cleaner power when it is available

Shift flexible workloads around grid conditions. Buy additional clean supply with hourly matching; Princeton modelling finds stronger emissions benefits than annual matching alone.

Choose cooling for the watershed

Use recycled water or closed-loop cooling where suitable. Publish local withdrawal, consumption and water stress; include any electricity tradeoff.

Cut the full company footprint

Report operations, electricity and supply-chain emissions separately. Reduce them before relying on removals for residual emissions; publish absolute totals alongside efficiency gains.

Try it: efficiency and growing demand

Total energy: 150% of the starting level

50% less per task × 3× as many tasks = 50% more total energy.

Arithmetic illustration, not a prediction. Total = energy per task × task count.

Company disclosures · progress, limits and methods worth sharing

Google

100%

Annual electricity matched with renewable purchases in 2025.

Company-wide emissions still totalled 18.85 million tonnes CO₂e on its GHG Protocol-aligned measure. Its separate “ambition-based” total uses exclusions and additional instruments.

Practice: shifting flexible computing workloads around grid conditions.

Microsoft

>90%

Of capacity served by closed-loop cooling at the featured Fairwater site.

A site design disclosure, not a measured fleet-wide water saving. Initial fill and other water uses remain.

Limit: Microsoft reported total emissions up 25% year on year in its 2026 report, despite annual renewable matching.

Amazon / AWS

26

Data centres using reclaimed water for cooling in its 2025 report.

Nearly 850 million litres of potable water substituted. That is not 850 million litres less total consumption.

Practice: reserve drinking-quality water by using treated wastewater where feasible.

Which claims describe future designs?

Microsoft’s next-generation cooling announcement projects over 125 million litres avoided per facility per year against its FY2024 average. It is a design comparison, not an observed fleet saving, and comes with a small electricity increase. Its schedule described 2026 pilots and new sites from late 2027.

Expert perspectives

Paraphrased views, not quotations or a claim of consensus.

Andrew A. Chien University of Chicago

Coordinate computing with the grid so flexible work can follow available clean power.

Emma Strubell Carnegie Mellon University

Efficiency per task can improve while growing use raises the total footprint.

How the evidence was selected

Primary university studies, government and intergovernmental reports, ethical-AI research and company disclosures published from September 2021–September 2026. This is a curated guide, not an exhaustive systematic review. Older underlying data are labelled.

Estimates, forecasts, surveys and observed results are kept distinct. Company claims are identified as disclosures. Charts are redrawn from cited data, with rounded values and calculated shares labelled; no missing years are interpolated.

Industry comparisons show scope and date because electricity, onsite water and supply-chain footprints are different measures. Findings do not automatically generalize beyond the studied people, products or settings.

Sources59 sources

Each “Notes” button gives the finding, scope and limits.

Download source ledger ↗
59 sources
2025 · Modelled estimate & scenarios

Energy and AI ↗

International Energy Agency

2025 · Peer-reviewed field study

Generative AI at Work ↗

Brynjolfsson, Li & Raymond · Quarterly Journal of Economics

Research notes